Lincoln Navigator: Transmission Cooling / Transmission Fluid Cooler - Backflushing and Cleaning. General Procedures
Special Tool(s) /
General Equipment
Transmission Cooling System Heated Flusher |
Materials
Name |
Specification |
Motorcraft® MERCON® ULV Automatic Transmission Fluid XT-12-QULV |
WSS-M2C949-A, MERCON® ULV
|
Flushing
-
NOTE:
Use transmission fluid specified for this
transmission. Do not use any supplemental transmission fluid additives
or cleaning agents. The use of these products could cause internal
transmission components to fail, which will affect the operation of the
transmission.
The transmission cooling system (cooler and lines) MUST
be flushed every time the transmission is overhauled or replaced in
order to minimize the likelihood of repeat repairs. It is mandatory that
proper equipment and procedures be followed when flushing
coolers/lines. The flushing equipment used MUST:
-
maintain fluid at 140°F or above,
-
pulsate fluid during cleaning,
-
have twin magnetic filters,
-
and have air purge capability before and after flushing.
-
If equipment meeting the specifications above is not
available, the transmission fluid cooler should be replaced and the
lines cleaned by hand.
-
Check and top off fluid level of the transmission cooling system heated flusher with transmission fluid.
Use the General Equipment: Transmission Cooling System Heated Flusher
Material: Motorcraft® MERCON® ULV Automatic Transmission Fluid
/ XT-12-QULV
(WSS-M2C949-A, )
(MERCON® ULV)
-
Turn on the heater and allow the fluid in the cooler
line flusher 15-30 minutes to heat up to 60°C (140°F) before using.
-
Install the line adapters on the transmission fluid cooler inlet and outlet tubes.
-
Attach the cooler line flusher red line to the
transmission fluid cooler inlet tube assembly. For the location of the
transmission fluid cooler inlet and outlet tubes.
Refer to: Transmission Cooling - Component Location (307-02 Transmission Cooling, Description and Operation).
-
Attach the cooler line flusher blue line to the transmission fluid cooler outlet tube assembly.
-
Follow the equipment instructions to purge the
transmission fluid cooler tubes and transmission fluid cooler prior to
starting the flushing procedure.
-
Allow the transmission fluid cooling system to backflush
for 10-15 minutes, then flush the transmission fluid cooler in a normal
flow direction for an additional 10-15 minutes.
-
If the transmission fluid cooling system heated flusher is equipped with an inspection micron filter:
-
Remove and clean the Oberg 28 micron filter.
-
Install the filter.
-
Backflush the system for 5 minutes.
-
Remove and inspect the filter.
-
If debris/contamination is present on the filter, repeat step 9.
-
Follow the equipment instructions to purge the transmission fluid cooler tubes and transmission fluid cooler.
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods (100-00 General Information, Description and Operation)...
Special Tool(s) /
General Equipment
Hose Clamp(s)
Materials
Name
Specification
Motorcraft® MERCON® ULV Automatic Transmission FluidXT-12-QULV
WSS-M2C949-A, MERCON® ULV
Removal
With the vehicle in N , position it on a hoist...
Other information:
Activation
NOTE:
Use Refrigerant Identification Equipment to identify
gas samples taken directly from the refrigeration system or storage
containers prior to recovering or charging the refrigerant system.
NOTE:
Use Refrigerant Identification Equipment that
conforms to SAE J1771 standard for R-134a or SAE J2912 standard
identifies R-134a and R-1234yf...
Removal
WARNING:
The following procedure describes critical repair steps
required for correct seat component installation. Follow all notes and
steps carefully. Do not place any objects between the seat components
and the body of the vehicle, nor any objects within a joint internal to
the seat structure...